Birthing Simulator PROMPT Flex - Advanced (Dark Skin Tone)
NEW! Augmented Reality has come to the PROMPT Flex Birthing Simulator: Combine the PROMPT Flex trainer, ART Mat and FREE ART app, for a dynamic experience of overlaid anatomy and captivating procedural animations, including spontaneous vaginal birth, breech Mauriceau-Smellie-Veit manoeuvre, and shoulder dystocia scenarios showing McRoberts, suprapubic pressure and internal manoeuvres.
The Advanced PROMPT Flex Birthing Simulator is an anatomically correct representation of a mother and baby. Its modular design allows for multiple training scenarios, and it forms the base for the complete PROMPT Flex range of birthing modules.
This birthing trainer offers a hybrid solution to your training needs. Quick and easy to set up straight from the box you are able to:
- Use as a stand alone model for group learning
- Secure to a bench top or bed for a more realistic bedside scenario to improve professional-patient communications
In addition to the functionality of the PROMPT Flex Standard model, this version of the PROMPT has a Bluetooth enabled Force Monitoring baby.
During labor there is a threshold of force that can result in brachial plexus injury during shoulder dystocia. The Force Monitoring Baby measures the force applied by trainees during drills. In conjunction with the Limbs & Things Birthing Simulator Software, instructors have the ability to record actions and interventions made, and the time to deliver the baby.
A simple meter mode in the software allows trainees valuable practice in applying force to the baby outside of the context of a scenario - enabling them to become familiar with the feel of both safe and excessive force before encountering a real obstetric emergency.
Översikt
- PROMPT Flex’s modular design allows for multiple training scenarios that you can tailor to your specific course needs
- Additional modules include: Postpartum Hemorrhage (PPH), Enhanced C-Section, Cervical Dilatation & Effacement (CD&E), Cervical Cerclage, Lower Legs, Compression Suture Uterus
- Baby model has improved shoulder and hip joints
- Bluetooth enabled baby allows for Force Monitoring with a scenario-based software (downloadable from the website)
- Drills run with the software can be recorded for later review
- Comes with wheeled carry case for safe storage and transportation
- The PROMPT Flex Range can offer a complete training solution for birth management
Realism
- Gynaecoid shape pelvis with soft, flexible birth canal, dilatable cervix and pelvic floor musculature provides realism in normal and complicated births
- Baby model represents a full term infant in weight and size, allowing for realistic handling
- Force Monitoring software allows trainees to accurately learn the safe amount of force that can be administered during delivery
Mångsidighet
Birthing Mother:
- Stand alone or hybrid use, 3 straps are supplied to secure PROMPT simulator for bench top or bed mounting
- Articulated thighs help to demonstrate Gaskin and McRobert’s procedures
- Handle on the base of the mannikin for operator use during labor simulation
- Can be used with additional modules to extend training simulations
Baby:
- Improved articulation of the joints offers enhanced realism for difficult birthing scenarios, such as shoulder dystocia
- Software is compatible with Windows, Mac, iOS and Andriod, and can be run on tablets as well as PCs
- User definable text in the software allows for intervention and birthing scenario names to be edited into the user’s native language
Rengöring
- Clean off excess lubricant from all mother and baby surfaces
- Wipe clean the product with a damp soft cloth, warm water and mild detergent
- NOTE: Force Monitoring Baby module contains electronics and should not be immersed in water when cleaning
- Allow the birthing trainer and its components to dry before storing
Säkerhet
- This product is latex free
- A poorly lubricated baby or placenta may damage the birth canal or cervix when pushed through during a procedure
- We recommend lubricating the cervix, birth canal and baby before each birth
- We recommend using Limbs & Things lubricant, non-recommended fluid products may weaken or damage the trainer
- Wear gloves at all times, and remove all sharp objects. Sharp surfaces (such as fingernails and rings) can lead to silicone damage
- Force Monitoring Baby contains electronic components, do not immerse in water
- EC Declaration of Conformity, in accordance with ISO IEC 17050-1:2010
- UKCA Declaration of Conformity, in accordance with UK Government Guidance
- FCC Declaration of Conformity, in accordance with standard 47CFR:2008 Part 15, Sub Part C, clauses 15.207 & 15.209
Simulerad patient
- The PROMPT Flex range offers multiple scenarios that can include patient simulation training
Anatomi
Anatomy of the PROMPT Birthing Mother:
- Birth canal and cervix
- Ischial spines and pubic bone
- Gynaecoid pelvis
- Articulating Thighs, with injection pad
- Abdomen
Anatomy of the PROMPT Baby:
- Umbilical cord and placenta (detachable)
- Clavicles
- Suture lines and fontanelles
Färdigheter
- Training and practice in the following types of birth:
- Normal
- Vaginal breech
- Shoulder dystocia with force feedback*
- Vaginal assisted (forceps and vacuum devices)
- Third stage of labour
- Cord prolapse
- Urinary catheter placement
- IM injection
- Communication and teamwork skills
*Force feedback is unique to this model and not available on the PROMPT Flex Standard
Bevis
Training for Shoulder Dystocia: A Trial of Simulation Using Low-Fidelity and High-Fidelity Mannequins.
Crofts, J. F., C. Bartlett, et al. (2006). "Training for Shoulder Dystocia: A Trial of Simulation Using Low-Fidelity and High-Fidelity Mannequins." Obstet Gynecol 108(6): 1477-1485.
Management of Shoulder Dystocia: Skill Retention 6 and 12 Months After Training.
Crofts, J. F., C. Bartlett, et al. (2007). "Management of Shoulder Dystocia: Skill Retention 6 and 12 Months After Training." Obstet Gynecol 110(5): 1069-1074.
Shoulder dystocia training using a new birth training mannequin.
Crofts, J. F. A., Georgios; Read, Mike; Sibanda, Thabani; Draycott, Timothy J. (2005). "Shoulder dystocia training using a new birth training mannequin." BJOG: An International Journal of Obstetrics & Gynaecology 112(7): 997-999.
Patient-actor perception of care: a comparison of obstetric emergency training using manikins and patient-actors.
Crofts, J. F. B., C; Ellis, D; Winter, C; Donald, F; Hunt, L P; Draycott, T J (2008). "Patient-actor perception of care: a comparison of obstetric emergency training using manikins and patient-actors." Quality & Safety in Health Care 17(1): 20-24.
Improving Neonatal Outcome Through Practical Shoulder Dystocia Training.
Draycott, T. J., J. F. Crofts, et al. (2008). "Improving Neonatal Outcome Through Practical Shoulder Dystocia Training." Obstet Gynecol 112(1): 14-20.
Shoulder Dystocia: Using Simulation to Train Providers and Teams.
Fahey, J. O. M., MPH, CNM; Mighty, Hugh E. MD (2008). "Shoulder Dystocia: Using Simulation to Train Providers and Teams." Journal of Perinatal & Neonatal Nursing 22(2): 114-122.
Comparison |
Product No. |
|
---|---|---|
Skills | 80200 | 80206 |
Training and practice in the following types of birth: | ||
Normal | Yes | Yes |
Vaginal breech | Yes | Yes |
Shoulder dystocia | Yes | Yes |
Shoulder dystocia with force feedback | No | Yes |
Vaginal assisted (forceps and vacuum devices) | Yes | Yes |
Third stage of labor | Yes | Yes |
Cord prolapse | Yes | Yes |
Urinary catheter placement | Yes | Yes |
IM injection | Yes | Yes |
Communication and teamwork skills | Yes | Yes |
-
-
-
-
-
-
Perineum & Birth Canal PROMPT Flex - Standard/Advanced (Dark Skin Tone)
Produktnummer. AAALT80225
Läs mer -
-
Comparison |
Product No. |
||
---|---|---|---|
What's included | 80200 | 80206 | |
80220 | Birthing Mother (with upper legs) | Yes | Yes |
80221 | Standard Baby | Yes | No |
80222 | Wireless Force Monitoring Baby (Bluetooth) | No | Yes |
80123 | Placenta | Yes | Yes |
80224 | Abdomen for PROMPT Flex | Yes | Yes |
80225 | Perineum and Birth Canal for PROMPT Flex | Yes | Yes |
10199 | PROMPT Birthing Lubricant (500ml) | Yes | Yes |
01000 | Wheeled Carry Case | Yes | Yes |
60133 | ART Mat for PROMPT Flex | Yes | Yes |
- | Birthing simulator software downloadable from the downloads tab | No | Yes |
-
-
-
-
Perineum & Birth Canal PROMPT Flex - Standard/Advanced (Dark Skin Tone)
Produktnummer. AAALT80225
Läs mer -
-
-
-
PLEASE NOTE:
The PROMPT Flex software may not be compatible on some Android devices
For instructions on how to install PROMPT Flex on MacOS, click here.
The PROMPT birthing simulators are listed as being modular in design, what does this mean?
Standard and Advanced birthing simulators comprise of a Birthing Mother and Baby model. The Limbs & Things PROMPT Flex range has several additional modules that can be used in combination with the birth simulator base.
- Lower Legs – articulated at the knee, these offer increased realism when used with the birthing mother
- Enhanced Cesarean Section module – suitable for the practice of routine and complex c-sections
- Postpartum Hemorrhage module – give training in the management of postpartum bleeding
- Cervical Dilation & Effacement module – develop assessment and management skills required during latent and active first stages of labor
- Compression Suture Uterus – additional module for practicing common types of compression sutures and ligating the uterine artery
- PPH Kit – this kit includes the postpartum hemorrhage module and compression suture uterus module for postpartum bleeding and compression suture and ligating of the uterine artery
- Cervical Cerclage module – practice of elective or emergency cerclage to prevent pre-term birth
What does this childbirth simulator offer to medical students?
As part of a birth simulation, trainees will get hands-on experience with our realistic labor simulator. Simulated births offer the chance to develop their communication and teamwork skills, as well as practice fundamental skills required during labour.
Will using the PROMPT Flex Birthing Simulator during training improve neonatal outcomes?
A retrospective study undertaken by Southmead Hospital, UK, showed that after the introduction of simulation training there was improvement seen in the management and outcomes of births complicated by shoulder dystocia. See the skills tab for more information on the study: Improving Neonatal Outcome Through Practical Shoulder Dystocia Training.