Den här dynan med mjukvävnad kan träs på över armen och inkluderar 3 raka vener, varav den ena är pedriatisk i storlek.
Highlights
Veins are:
- Self-sealing for repeated use
- Replaceable
- Rechargeable via a one-way valve
- Supplied with mock blood under pressure
Realism
- Can be used with Standardized/Simulated Patient. Straps onto the arm or back of the hand
Versatility
- The pad can be connected to the Mock Blood Giving Set (Product No. 60651) to simulate blood flow. Only for use with Mock Blood - Venous (Product No. 00223)
Anatomy
- Lumen sizes of veins (1 of each): 1mm, 4mm, 6mm
Cleaning
- Washable using soap and water
- Epidermis is replaceable
Safety
- Tough backing plate to prevent needle stick injuries
- These veins contain latex
Weight & Dimensions
- Weight: 0.22 kg
- Width: 12 cm
- Height: 6 cm
- Length: 15 cm
Skills Gained
- Kommunikation mellan läkare och patient
- Instickning av nål
- Insättning av kanyl
- Hantering av blodflöde
Weight & Dimensions
- Weight: 0.22 kg
- Width: 12 cm
- Height: 6 cm
- Length: 15 cm
Works with the following products:
References
Practical Skills and Procedures, General Medical Council, April 2019, p.4 & 5
Diagnostic Procedures
5. Take blood cultures: take samples of venous blood to test for the growth of infectious organisms
7. Carry out venepuncture: insert a needle into a patient's vein to take a sample of blood for testing.
NMC Future nurse: Standards of proficiency for registered nurses, 17 May 2018, p.32 2.2 undertake venepuncture and cannulation and blood sampling, interpreting normal and common abnormal blood profiles and venous blood gases
Royal Marsden Manual 9th Ed (2015). Procedure guideline 10.1 Venepuncture. Select the vein by careful palpation; use 23-gauge winged infusion device for small veins; Anchor the vein by applying manual traction on the skin; Insert the needle smoothly at an angle of approx. 30 degrees; reduce the angle once flashback of blood is seen; withdraw blood; remove needle; inspect puncture point before applying a dressing. Procedure guideline 14.4: Peripheral Cannula insertion: Assess and select vein; Anchor the vein; hold the cannula in the dominant hand, ensure it is in the bevel up position; insert the cannula through the skin; wait for first flashback of blood and then withdraw the stylet slightly; advance the cannula; attach a primed extension set, needless injection cap or administration set.
NHS National Practitioner Program: Matrix Specification for the Physician Associate (2016). p.127: Core Procedural Skills: Venepuncture; IV cannulation
Specialty Training Curriculum For Core Medical Training, 20013 (p.165): The CMT StR is expected to be competent, and maintain competency, in the following practical procedures in the Foundation curriculum during Core Medical Training: ...Venepuncture
GMC Outcomes for provisionally registered doctors with a licence to practise (The Trainee Doctor), 2015 p. 8: Core clinical and procedural skills ...: Venepuncture, IV cannulation